iGET SECURITIES P6 - wireless detector gas
Code: 75020206Product detailed description
Depending on the location it is possible to detect natural gas (LNG, CNG), Coal gas, Propane butane (LPG) and petroleum substances.
- for boilers
- in the garage for a car with LPG, LNG, CNG.
- the detector is designed for all rooms where gas level monitoring is necessary,
- once the gas is detected, the warning LED will flash red and the detector siren will sound,
- the detector can also be wirelessly connected to the iGET SECURITY M3B and M2B alarms for guaranteed comprehensive protection. The alarm will also sound a siren and send an SMS when it receives an alarm signal,
- the detector operates at 433 MHz, so it can be used with many other brands of alarms that operate at the same frequency,
- simple extension of the basic alarm set iGET SECURITY,
- includes a test button to check functionality.
Possible location and use of the detector:
- Gases that are lighter than air, rise, the detector to place to the ceiling:
Place the detector at a height of 15 to 30 cm below the ceiling, and 60 cm from the corners, i.e. from the point where the two walls converge. It must be at least 1.2 m from the gas source to prevent false alarms. These are:
- Natural gas (LNG, CNG),
- Coal gas.
- Gases that are heavier than air, sink to the ground, the detector place to the ground:
Place the detector at a height of 15 to 30 cm above the ground and 60 cm from the corners, i.e. from where the two walls converge. Must be at least 1.2m from the gas source to prevent false alarms. These are:
- Propane butane (LPG),
- Petroleum substances.
Broadcast frequency: 433 MHz
Coding used: 2262/1527
Operating temperature: +10°C ~ +50°C
Operating humidity: 20%~90%
Environment: dry, indoor
Supply voltage: 230V, 50~60 Hz
Consumption : 2 ~ 3 W
Siren: 90 dB
Reaction: about 60 seconds
Sensitivity:
Coal gas: 2~5% LEL
Natural gas: 10~25% LEL
Propane butane: 10~25% LEL
(LEL = lower explosive limit)
Signal range to the central unit:
up to 50 m. in direct visibility